1. |
Disconnect the M-terminal (A) on the magnet switchassembly.
|
2. |
After loosening the 2 screws (A), detach the magnetswitch assembly
(B).
|
3. |
Loosen the brush holder mounting screw (A) and the trough bolts
(B).
|
4. |
Remove the rear bracket (A) and brush holderassembly (B).
|
5. |
Remove the yoke (A).
|
6. |
Remove the packing (A), lever plate (B), lever (C), armature (D).
|
7. |
Press the stopper (A) using a socket (B).
|
8. |
After removing the stop ring (A) using stopper pliers (B).
|
9. |
Remove the stop ring (B), stopper (A), overrunningclutch (C) and
armature (D).
|
Components
1. Union bolt
2. Gasket
3. Tube joint
4. Clutch tube
5. Valve plate
6. Valve spring
7. Bleeder screw
8. Release cylinder
9. Return spring
10. Piston
11 ...
Fluid Service Adjustment Procedure
Oil level Check
A check of ATF level is not normally required during scheduled
services. If an oil leak is ...
Heater & A/C Control Unit (MANUAL) Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the heater & A/C controller (A) from the center facia using
a flat-head scre ...