1. |
Disconnect the stop lamp switch connector (A).
|
2. |
Adjust the brake pedal height (A) as illustration below.
|
3. |
Adjust the stop lamp switch clearance (B).
|
4. |
Connect the stop lamp switch connector.
|
1. |
Disconnect the stop lamp switch connector (A).
|
2. |
Pull the locking plate (A) as indicated by the arrow.
|
3. |
Turn stop lamp switch 45° counterclockwise and remove it.
|
4. |
Fix the brake pedal arm and insert fully the stop lamp switch
as hiding contact part.
|
5. |
After inserting, turn the stop switch (A) 45° clockwise, and then
assemble locking plate (B) by pushing.
|
6. |
Confirm the gap between stop lamp switch and bracket.
|
7. |
Connect the stop lamp switch connector.
|
Inspection
Horn Inspection
Test the horn by connecting battery voltage to the 2 terminal and ground
the 1 terminal.
1 : 12V Ground(-)
2 : 12V (+)
...
Accelerator Pedal Removal
1.
Turn the ignition switch OFF and disconnect the negative (-) battery
cable.
2.
Disconnect the accelerator position sensor connector (A). ...
Installation
1.
Dowel pin of crankshaft setted about 3° with vertical center line.
2.
Align the TDC marks (A) of the CVVT sprockets with the upper su ...