1. |
Turn the ignition switch OFF.
|
2. |
Disconnect ambient temperature sensor.
|
3. |
Check the resistance of ambient temperature sensor between terminal
“+” and “-” whether it is changed by changing of the ambient temperature.
Specification
|
4. |
If the measured resistance is not within specification, substitute
with a known-good ambient temperature sensor and check for proper operation.
|
5. |
Replace the ambient temperature sensor if it is proved that there
is a problem with the sensor.
|
Installation
•
Install the component with the specified torques.
•
...
DC/DC Converter: Removal and Installation
1.
Disconnect the battery negative terminal.
Tightening torque
Without battery sensor :
7.8 ~ 9.8 N.m (0.8 ~ 1.0 kgf.m, 5.8 ~ ...
Evaporator Temperature Sensor Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the evaporator temperature sensor connector.
3.
Measure resistan ...