1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the foot connector.
|
3. |
Verify that the foot actuator operates to the open position when
connecting 12V to the terminal 3 and grounding terminal 4.
Verify that the foot actuator operates to the close position when
connecting in the reverse.
|
4. |
Connect the foot actuator connector.
|
5. |
Turn the ignition switch ON.
|
6. |
Check the voltage between terminals 6 and 5.
Specification
With auto defogging activated
With auto defogging deactivated
It will feedback current position of actuator to controls.
|
7. |
If the measured voltage is not within specification, substitute
with a known-good foot actuator and check for proper operation.
|
8. |
Replace the foot actuator if it is proved that there is a problem
with it.
|
Blower Resistor (MANUAL) Inspection
1.
Measure the resistance between the terminals.
2.
The measured resistance is not within specification, the blower
resistor must be replac ...
Transmitter Inspection
1.
Check that the red light flickers when the door lock or unlock
button is pressed on the transmitter.
2.
Remove the battery and check vol ...