1. |
Installation is the reverse of removal.
|
Rear Washer Switch Inspection
1.
With the rear wiper & washer switch in each position, make sure
that continuity exists between the terminals below. If continuity is
not as specified, replace t ...
Back-up Lamp Switch Inspection
1.
Disconnect the back up lamp switch connector (A).
2.
Check the continuity between no. 1 and 2 terminals of backup lamp
switch. W ...
Description
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and
controls the passage between the canister and the intake manifold. It is a solenoid
valve and is open when the ECM groun ...