1. |
Place the shift lever into the "N" position.
|
2. |
Remove the air cleaner assembly.
|
3. |
Remove the battery and the battery tray.
(Refer to "Charging system" in EE group.)
|
4. |
Disconnect the inhibitor switch connector (A).
|
5. |
Remove the shift cable mounting nut (B).
|
6. |
Remove the manual control lever (B) and the washer after removing
a nut (A).
|
7. |
Remove the inhibitor switch (A) after removing the bolts (2ea).
|
Circuit Diagram
...
Starter: Components
1. Screw
2. Front housing
3. Stop ring
4. Stopper
5. Overunn clutch
6. Lever
7. Lever plate
8. Lever packing
9. Magnet switch assembly
10. Armature assemb ...
SRS Control Module (SRSCM) Variant coding
After replacing the SRSCM with a new unit, the “Variant Coding” procedure
must be performed.
1.
...